Battery Cyclers.
Modularity, performance, power and flexibility
BioLogic® offers a comprehensive line-up of battery cyclers, designed to support every stage of the battery development cycle through two complementary instrument ranges: Premium and Essential.
The Premium range includes the ultra-precision BCS-900 Series, delivering modularity, accuracy, and precision across R&D, pilot production, quality control, and certification. It also features the MPG-200 Series, a flexible and high-performance platform tailored for research-focused applications.
The Essential range is represented by the BCS-1012 Series—a high-throughput system designed for demanding aging studies, with 32 independent channels and a maximum current of ±6 A per channel.
Together, these solutions form a versatile and reliable portfolio that serves the needs of both industry and academia—from early-stage research to large-scale testing.


BioLogic Battery Cyclers.
A complete solution for advanced battery testing and data analysis
BioLogic’s battery cyclers support the entire development cycle—from research to high-throughput testing.
The BCS-900 Series offers precision and flexibility for advanced applications, including native EIS – While the BCS-1012 Series provides scalable performance for aging studies.
A the heart of the solution lies BT-Lab® Suite, enabling on-site and remote access, batch data analysis, and easy reporting. With climate chamber control, and automation tools, BioLogic delivers a seamless, integrated testing experience.
Our range of Battery cyclers.
An instrument for every possible need
Essential Battery Cyclers
The Essential range, featuring the BCS-1012 Series, delivers reliable, high-throughput testing for large-scale aging studies and routine cycling. With built-in climate chamber control and modular capabilities, it offers a cost-effective solution for production environments and testing labs seeking scalable, efficient performance without compromising on quality.
ESSENTIAL
BCS-1012
Channels: 32 in 8U
Current: 6A / 600mA / 60mA
Voltage: 0 to 5 V
BT-Lab® Suite based
Premium Battery Cyclers
The Premium range, including the BCS-900 Series, offers cutting-edge technology designed for high-precision testing across R&D, pilot production, quality control, and certification. With advanced features like native EIS, climate chamber control, and seamless integration with BT-Lab® Suite, these systems provide unmatched performance for the most demanding applications.
PREMIUM
BCS-900
Channels: 8 per module
Current: Up to 5 per module
Native EIS: Up to 10kHz
Voltage: from -7.5 V to 10 V
BT-Lab® Suite based
PREMIUM RESEARCH
MPG-200
Channels: 8 per module
Current: Up to 5 per module
Native EIS: 10 μHz to 100 kHz
Voltage: from -10 V to 10 V
EC-Lab® based
BCS-975R / 75 A / 300 A
3 ranges: 75 A / 7.5 A / 750 mA
Parallelization allows 4*150 A / 2*300 A
Regenerative
0 V to 5 V
BCS-915 / 15 A / 120 A
5 ranges: 15 A down to 1.5 mA
Parallelization:
1*120 A / 2*60 A / 4*30 A
0 V to 9 V
BCS-1012 / 6 A
3 ranges: 6 A / 600 mA / 60 mA
0 V to 5 V
BCS-910 / 1.5 A
5 ranges: 1.5 A down to 150 µA
0 V to 10 V
or -5 V to +5 V (/n)
BCS-905 / 150 mA
5 ranges: 150 mA down to 15 µA
0 V to 10 V
or -2.5 V to +7.5 V (/n)

BT-Lab® Suite software.
BT-Test™ integrates cutting-edge features that empower researchers with unparalleled control and flexibility in designing, running and monitoring cycling experiments. Researchers can effortlessly manipulate variables to tailor experiments to their exact specifications, ensuring the generation of highly accurate and insightful data.
For demanding battery data processing, in-depth and automated analysis is completed with BT-Analysis™. Analyses are tailored to specific needs with unmatched flexibility. Access to critical data anytime, anywhere – online or offline – ensures key data is never missed.

BT-Test™.
Get superior performance in battery testing software.For cycling control, acquisition and monitoring
- Application oriented interface
- User-friendly grid
- Manage variables for test automation
- Flexible user management for confidentiality
Test run monitoring and acquisition
- Global view of channel status
- Local and remote setup and monitoring
- Activity log access
- On-the-fly test modifications
- Live data display
- Flexible text export
For cycling control, acquisition and monitoring
- Application oriented interface
- User-friendly grid
- Manage variables for test automation
- Flexible user management for confidentiality
Test run monitoring and acquisition
- Global view of channel status
- Local and remote setup and monitoring
- Activity log access
- On-the-fly test modifications
- Live data display
- Flexible text export
BT-Analysis™.
Get maximum efficiency with automated batch data processing.Automated and flexible test analysis
- Online and off-line data access
- Application oriented graphs, tables and statistical tools
- Refresh displays of multiple sets of data in real time
- Display data in multiple formats including cycles, loops
Test reporting and export
- Generate displays for reports during tests
- Flexible and customizable graph formatting
- Recipes for automatic graph and table generation
- Export tables and formatted graphics
Automated and flexible test analysis
- Online and off-line data access
- Application oriented graphs, tables and statistical tools
- Refresh displays of multiple sets of data in real time
- Display data in multiple formats including cycles, loops
Test reporting and export
- Generate displays for reports during tests
- Flexible and customizable graph formatting
- Recipes for automatic graph and table generation
- Export tables and formatted graphics
Which Battery Cycler best suits your needs?
The BCS Essential Battery Cycler Range: High-throughput Aging and Validation
Ideal for battery screening and aging studies, the BCS-1012 delivers cost-effective performance without compromising the quality standards you expect from BioLogic. The high channel density allows you to maximize your testing capacity up to 6 A – Perfect for cylindrical cells.
The BCS Premium Battery Cycler Range: Modularity, Flexibility and Power
Perfect for industry or academics requiring high-quality, high-throughput performance.
Modularity, flexibility, and high-end analytical performance are the keywords that define the BCS battery cycler range: a highly modular, state-of-the-art, battery cycling system built for industry. This rackable, high-throughput system will enable you to carry out multiple experiments on the same instrument, helping you to reduce capital outlay for R&D infrastructure. And with 8 channels per module, a voltage range of 0-9/10 V, and integrated EIS, the BCS battery cycler series will answer all your battery testing needs.
Supported by BT-Lab® Suite, our proprietary battery cycler control software, users can easily automate testing protocols and batch data analysis. With remote or on-site access you can
The MPG battery tester series: Precision, stability and high-end analysis
Perfect for in-house R&D or academia
Precision, stability, and advanced electrochemical techniques and analyses are the keywords that define BioLogic’s MPG range of battery cyclers. These instruments stand out for their 7 current ranges and their negative voltage as well as ultra-fast acquisition times. This, and the fact that they are the only battery cyclers on the market to give users a real reference electrode management make them perfect instruments for research and development applications.
Real workhorses, MPG battery testers will run and run with minimal maintenance, delivering results with unparalleled levels of quality and precision.
This range of benchtop R&D grade battery cyclers runs off EC-Lab® software, an industry benchmark in electrochemistry control software, so you can easily transition from BioLogic’s potentiostat/galvanostats to battery cycling without having to familiarize yourself with new software.
Why choose BioLogic® Battery Cycler?
Adaptable & Scalable
As battery technologies and testing needs continue to evolve, BioLogic’s modular battery cyclers provide the ultimate flexibility and adaptability to meet the demands of your research. Our innovative BT-Lab software allows you to seamlessly modify experiments on the fly, eliminating the need for rigid pre-planning. Our modular design enables you to effortlessly expand the capabilities of your battery cycler as your research requirements grow, ensuring that you always have the tools you need to conduct groundbreaking research.
Native Electrochemical Impedance Spectroscopy
BioLogic’s integrated EIS capability empowers researchers to gain a deeper understanding of battery behavior, accelerating the development of new battery technologies. Native EIS integration streamlines the testing process, while ZFit analysis software facilitates accurate data interpretation. Embrace the powerful EIS capabilities of BioLogic to revolutionize battery technology.
High-precision, High-accuracy
Our battery cyclers embody BioLogic’s commitment to delivering exceptional precision, accuracy, and resolution. With 2 ms continuous sampling and process rates, the BCS-800 series ensures precise measurements across a wide range of battery capacities and C-rates. Smooth CC-CV switching and low standard deviations between channels further enhance measurement quality.
See more articles on our Learning Center.
- Read the article
Introducing Symmetric Cells
Introduction to symmetric cells and their DC and AC electrochemical response.
- Read the article
The Gerischer Impedance
What exactly is the Gerischer impedance and which systems can be modelled with it?
- Read the article
What are All-Solid-State Batteries
Discover key differences from traditional lithium-ion batteries, ongoing research challenges, and instrumentation requirements
- Read the article
What is a battery cycler?
What should I know about battery testing equipment?
Need support?
my.biologic.net
Register my instruments
Request a quote
Need support?